AEG Uneven Brush or Spray Distribution

Carpet cleaner leaves streaks or uneven cleaning lines on the carpet.

Advertisements

Possible Causes

Partially clogged spray jets, Worn or uneven brush bristles, Misaligned floor nozzle, Build-up on nozzle squeegee

How to Fix / Troubleshooting

Safety first: Unplug the appliance before cleaning the nozzle or brush.

  • Clean spray jets: Remove the nozzle and thoroughly clean each jet with warm water and a soft brush to ensure even spray.
  • Inspect brush roll: Check for flattened or missing bristles. Replace the brush roll if bristles are worn unevenly.
  • Clean squeegee and nozzle lip: Wipe away detergent residue and lint from the squeegee and nozzle edges.
  • Check nozzle alignment: Ensure the nozzle is correctly seated and not warped. Reinstall firmly so it sits flat on the carpet.

Regular cleaning of the nozzle and brush helps maintain consistent cleaning performance.