E10
Bosch
Low Voltage / Input Supply Error
Display shows E10; unit powers but neither suction nor brush motor starts
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Undervoltage from mains, Faulty internal power supply module, Loose neutral or live connection, Damaged line filter board
How to Fix / Troubleshooting
Safety first: Disconnect from mains before opening the unit. Work on mains circuitry only if you are trained and competent.
- 1. Verify mains voltage
- Test the wall outlet with a multimeter or another appliance to ensure stable voltage.
- Avoid using long extension leads or multi-way adapters that may cause voltage drop.
- 2. Inspect power inlet and line filter
- Remove the rear or bottom cover to access the power inlet and line filter PCB (if fitted).
- Check for loose spade connectors, burnt components, or cracked solder joints.
- Reseat connectors and replace the line filter board if damaged.
- 3. Check internal power supply
- Locate the low-voltage power supply module on the main PCB.
- If indicator LEDs on the board are off or flickering, the supply may be failing.
- Replacement of the main control PCB or power module is recommended rather than component-level repair.
- 4. Professional service
- Because this error involves mains and low-voltage electronics, a Bosch-authorized technician should perform final diagnosis and replacement.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Line Filter / Power Supply Module
Check Price on Amazon