Excessive Solution Usage
Solution tank empties very quickly with minimal cleaning time.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Leaking solution hose or connection, Stuck-open solution valve, Overly large spray pattern due to wrong nozzles, User holding trigger continuously
How to Fix / Troubleshooting
Safety: Unplug and empty tanks before inspection.
- Inspect for leaks: Fill the solution tank with water and observe hoses and connections for drips.
- Check valve: Ensure the solution valve closes when the trigger is released. Replace if it remains open.
- Use correct nozzles: Verify that only Ewbank-specified nozzles are installed.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Solution Valve Assembly
Check Price on Amazon