Possible Causes

Overheating suction motor, Clogged filters restricting airflow, Loose power cord connection, Failing thermal cut-out

How to Fix / Troubleshooting

Safety: Unplug the unit and allow it to cool before inspection.

  • Clean filters and check airflow: Wash intake filters and clear all blockages in hose and nozzle.
  • Inspect cord and plug: Wiggle the cord gently near the plug and machine entry; if power cuts, replace the cord.
  • Avoid long continuous use: Allow cooling breaks during extended cleaning sessions.

If shutoffs continue after cleaning and cord checks, the motor or thermal cut-out may need replacement.