E14
George
Accessory Power Outlet Fault
No power to powered hand tool (if using an electric turbo or brush tool from George accessory kit)
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty accessory power socket, Broken internal accessory wiring, Blown accessory fuse (if fitted), Damaged powered tool cable
How to Fix / Troubleshooting
Safety: Unplug the machine and disconnect the accessory.
- Test accessory on another unit: If possible, test the powered hand tool on another compatible George or Numatic machine to confirm if the tool or base unit is faulty.
- Inspect accessory cable: Check for cuts or kinks. Replace the powered hand tool cable if damaged.
- Check accessory socket: Inspect the socket on the George body for bent pins or looseness. Replace the accessory power socket if damaged.
- Check internal fuse: Some models have a small fuse on the accessory power circuit on the PCB. Replace with the exact rating if blown.