E17
George
Internal Solution Leak
Water leaking from base of machine during carpet extraction
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Cracked solution hose inside body, Loose hose clamp on pump outlet, Split solution tank outlet seal, Leaking pump housing
How to Fix / Troubleshooting
Safety: Unplug the machine and empty both clean and dirty tanks before opening.
- Inspect external hoses: Check visible solution hoses for drips while the tank is filled (machine unplugged). Tighten any loose clamps.
- Open body panels: Remove the top cover to access internal solution lines. Look for wet areas around the solution pump and hoses.
- Replace damaged hoses: Any split or brittle hose should be replaced with the correct diameter solution hose and secured with new clamps.
- Check tank outlet seal: Inspect and replace the solution tank outlet seal if it is cracked or flattened.