E20
George
Non-Return Valve / Trigger Valve Not Sealing
Solution continues to drip from nozzle after releasing trigger
Advertisements
Possible Causes
Worn trigger valve seat, Debris on valve seal, Faulty non-return valve in solution line, Excessive system pressure
How to Fix / Troubleshooting
Safety: Unplug and depressurize system.
- Clean nozzle and valve: Remove the spray nozzle and trigger valve. Rinse thoroughly to remove grit or fibers.
- Inspect valve seat: Check the trigger valve seat and seal for nicks or deformation. Replace if worn.
- Check non-return valve: Locate any inline non-return valve in the solution hose and ensure it moves freely. Replace the non-return valve if stuck.
- Reduce pressure: Avoid leaving the pump running continuously without spraying; cycle the trigger to relieve pressure.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Trigger Valve Seat
Check Price on Amazon