E8
Gorenje Solution Flow Sensor or Flow Restriction Error

Display shows E8; pump runs but no solution reaches the nozzle, and the machine quickly stops spraying.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked solution nozzle, Clogged internal solution hose, Faulty flow sensor, Kinked hose between tank and pump

How to Fix / Troubleshooting

Safety first: Unplug the unit and relieve any pressure in the solution line by squeezing the trigger with the machine off.

  • Clean the spray nozzle: Remove the floor nozzle or spray tip. Soak it in warm water with mild detergent and use a soft brush or toothpick to clear mineral deposits.
  • Inspect solution hoses: Check visible hoses from the tank to the pump and from the pump to the nozzle for kinks, pinches, or damage. Straighten or replace as needed.
  • Flush the system: Fill the clean water tank with warm water only. Reinstall and run the pump briefly to flush any air or debris, collecting water into a bucket.
  • Check flow sensor (if equipped): Some Gorenje models have an in-line flow sensor. Ensure its connectors are secure and that the sensor body is not clogged. Remove and rinse if accessible.
  • Replace faulty components: If the flow sensor is defective or the hose is internally collapsed, replace the affected part and re-test.
Advertisements

Repair Difficulty

Medium 3/5