E08
Husqvarna
Solution Flow / Pressure Fault
Display shows E08; solution pump runs but no water is sprayed, or spray is extremely weak
Advertisements
Possible Causes
Airlock in solution pump, Blocked inlet filter in solution tank, Cracked or leaking solution hose, Partially blocked spray bar
How to Fix / Troubleshooting
Safety: Unplug the Husqvarna carpet cleaner and remove the solution tank.
- Bleed air from system: Fill the Husqvarna solution tank with warm water only. Reseat it firmly. Plug in, then hold the trigger for 30–60 seconds to purge air from the pump (do not run dry for long).
- Clean tank inlet filter: At the bottom of the solution tank, locate the inlet screen or valve. Rinse under warm water and gently brush away debris.
- Inspect hoses for leaks: With the tank installed and trigger pressed, look for drips or wet spots along the clear solution hoses. Replace any cracked or brittle hoses.
- Clean spray bar: Remove the front nozzle/spray bar assembly. Soak in a descaling solution if you have hard water deposits. Use a soft brush to clear each jet.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Solution Hose and Spray Nozzle Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements