E10
Husqvarna Trigger / Handle Switch Fault

Display shows E10; trigger is pulled but no solution is dispensed, even though pump is not running

Advertisements

Possible Causes

Failed trigger microswitch, Broken trigger lever, Disconnected handle wiring harness, Faulty input circuit on main PCB

How to Fix / Troubleshooting

Safety: Unplug the Husqvarna carpet cleaner before opening the handle assembly.

  • Inspect trigger mechanism: Remove screws from the handle housing and separate the halves. Check that the plastic trigger fully depresses the microswitch when pulled.
  • Test microswitch: Use a multimeter in continuity mode across the switch terminals. Pull the trigger; continuity should appear when pressed. Replace the Husqvarna trigger switch if it fails this test.
  • Check handle wiring: Ensure the small harness from the handle to the main body is not broken or pinched. Reseat connectors at both ends.
  • PCB input check: If the switch and wiring are good, the main board may not be recognizing the trigger signal. Replacement of the main PCB may be required.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Trigger Microswitch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements