E12
Husqvarna
Solution Level / Flow Sensor Fault
Display shows E12; unit runs but indicates a sensor error, often related to water level or flow
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty optical or float-type solution level sensor, Mineral buildup on sensor window, Disconnected sensor harness, Failed sensor input on PCB
How to Fix / Troubleshooting
Safety: Unplug the Husqvarna carpet cleaner and remove the solution tank.
- Clean sensor area: If your model uses an optical sensor in the tank cavity, wipe the sensor window with a soft cloth and warm water to remove detergent film.
- Check float sensor: For float-type sensors, ensure the float moves freely and is not waterlogged. Replace the float or sensor assembly if it sticks.
- Inspect wiring: Verify that the sensor connector is fully seated on the main board and that the harness is not damaged.
- Board diagnosis: If a known-good sensor still triggers E12, the main PCB sensor input may be defective and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Solution Level Sensor
Check Price on Amazon