Husqvarna
Floor Spray Path Blockage
Solution sprays from accessory hose but not from the main floor nozzles
Advertisements
Possible Causes
Clogged floor spray bar, Diverter valve stuck in accessory mode, Kinked floor solution hose, Debris in floor nozzle inlet
How to Fix / Troubleshooting
Safety: Unplug the Husqvarna carpet cleaner and remove the floor nozzle.
- Clean floor spray bar: Remove and soak the floor spray bar in warm water. Clear each jet with a soft brush.
- Check diverter: Ensure the solution diverter returns to floor mode when the accessory hose is removed. Clean and free any sticking parts.
- Inspect hoses: Follow the solution hose from the diverter to the floor nozzle and straighten any kinks.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Floor Spray Bar
Check Price on Amazon
We may earn a commission from links on this page.