Morphy Richards
Poor Extraction / Inadequate Vacuum Recovery
Excessive water left in carpet, long drying time
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty water tank not sealing, Blocked suction path at floor head, Worn or damaged floor head squeegee, Weak suction motor
How to Fix / Troubleshooting
Safety: Unplug before inspection.
- Check tank seals: Inspect the dirty water tank gasket and lid. Replace if cracked or misshapen.
- Clean floor head: Remove the nozzle window and clear any lint or hair blocking the suction slot.
- Inspect squeegee: Examine the rubber squeegee blade on the floor head. Replace if torn or hardened.
- Test suction: With tanks fitted, place your hand over the suction inlet. If suction is weak despite clear paths, the suction motor may be failing and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Floor Head Squeegee Blade
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements