Possible Causes
Low suction due to leaks, Blocked vacuum intake slot at floor head, Worn or missing floor head squeegee, Moving machine too quickly during extraction
How to Fix / Troubleshooting
Safety: Unplug the unit before inspecting the floor head.
- 1. Check suction performance: Verify that the recovery tank, lid, and gaskets are sealing properly and that suction is strong at the hose.
- 2. Inspect intake slot: Turn the machine over and clean the vacuum intake slot at the floor head. Remove lint, hair, and debris.
- 3. Check squeegee: Inspect the rubber squeegee or vacuum shoe at the front or rear of the head. Replace if torn, hardened, or missing.
- 4. Adjust technique: Make slower extraction passes without spraying, allowing the vacuum to remove more moisture.
Tip: Use additional dry passes after cleaning to speed drying time.