Rug Doctor No Solution Flow from Tank

Rug Doctor carpet cleaner solution tank remains full; no solution is used during cleaning even though the pump can be heard.

Advertisements

Possible Causes

Stuck or blocked tank bottom valve, Air leak at tank seal, Disconnected solution pickup tube, Blocked inlet filter at base

How to Fix / Troubleshooting

Safety: Turn off and unplug the unit before removing the tank.

  • 1. Test tank valve: Remove the solution tank and press the bottom valve stem. Water should flow. If not, clean or replace the valve.
  • 2. Inspect tank seal: Check the tank-to-base seal for damage or misalignment. Replace if it does not seal tightly.
  • 3. Check pickup tube: Access the base and verify the solution pickup tube is connected from the tank port to the pump. Reattach if disconnected.
  • 4. Clean inlet filter: Clean any inlet screen or filter at the tank connection point.

Tip: Always seat the tank firmly to engage the valve and seal.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Solution Tank Valve Assembly
Check Price on Amazon