Russell Hobbs
Brush Drive Failure
Brush bar not spinning while suction and spray work normally.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Broken brush drive belt, Jammed brush bar, Failed brush motor, Disconnected brush motor wiring
How to Fix / Troubleshooting
Safety first: Unplug and remove tanks before turning the unit over.
- Clear debris: Remove hair and threads from the brush bar and end caps.
- Inspect belt: Remove the brush cover and check the belt. Replace if snapped, stretched, or melted.
- Check brush motor: With the belt removed, spin the motor pulley by hand; it should turn smoothly. If seized, the motor must be replaced.
- Reconnect wiring: Ensure the brush motor connectors are firmly attached.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Brush Drive Belt
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements