SEBO
Intermittent Hose Wiring or Connection Fault
Machine turns off when hose is fully extended or rotated
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Broken conductor in hose cable, Loose hose-end connector, Worn contacts in swivel joint, Strained internal wiring
How to Fix / Troubleshooting
Safety first: Unplug the machine before manipulating the hose.
- Reproduce the fault: With the machine plugged in and running (exercise caution), gently extend and rotate the hose to see if movement causes power loss. Then unplug before further work.
- Inspect hose ends: Check both ends of the hose for loose or damaged electrical contacts (on models with powered heads).
- Replace hose assembly: A broken conductor inside the hose cannot be reliably repaired. Replace the complete SEBO electrified hose assembly.
- Check swivel joint: If the fault occurs when rotating the hose at the body, the swivel contacts may be worn and require replacement by a technician.
Intermittent electrical connections can cause arcing and heat; address promptly.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
SEBO Electrified Hose Assembly
Check Price on Amazon