Siemens Mechanical Brush Drive Failure

Brushes do not spin, but there is suction and spray

Advertisements

Possible Causes

Broken or stretched brush belt, Debris jammed in brush roll, Worn brush bearings, Disengaged brush clutch (if equipped)

How to Fix / Troubleshooting

Safety: Unplug the unit and lay it on its back for access.

  • Remove debris: Cut away hair, threads, and fibers wrapped around the brush roll and end caps.
  • Inspect belt: Remove the belt cover and check the belt condition. Replace if cracked, stretched, or broken.
  • Check brush bearings: Spin the brush roll by hand. If it feels rough or seized, replace the brush roll assembly.
  • Verify clutch engagement: If your Siemens model has a brush on/off selector, ensure it is set to ON and the linkage is intact.

After replacing the belt or brush roll, reassemble and test on a small area of carpet.