Vax
Air Leak in Suction Path
High-pitched whistling noise and reduced suction
Advertisements
Possible Causes
Damaged tank seals, Cracked nozzle or hose, Misfitted dirty water tank lid, Missing or misaligned gasket
How to Fix / Troubleshooting
Safety first: Unplug the machine before checking seals and hoses.
- Check tank lid and seals: Ensure the dirty water tank lid is properly closed and the gasket is intact. Replace the gasket if flattened or torn.
- Inspect nozzle and hose: Look for visible cracks or holes. Run your hand along the hose while the machine is running (for brief tests) to feel for escaping air.
- Replace damaged parts: Fit a new hose, nozzle, or gasket where leaks are found.
- Ensure correct assembly: Refit all components firmly until they click into place to maintain a good seal.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Dirty Water Tank Gasket
Check Price on Amazon
We may earn a commission from links on this page.