E09
Vileda Motor Speed / Tachometer Error

Carpet cleaner shows E09 and shuts down shortly after starting; the motor sounds unusually loud or unbalanced.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty motor tachometer sensor, Loose motor fan causing imbalance, Damaged motor bearings, Faulty speed control circuit on PCB

How to Fix / Troubleshooting

Safety: Unplug the unit and allow it to cool before opening.

  • Inspect motor fan: Access the suction motor and check that the plastic fan is firmly attached to the shaft and not cracked. Replace the motor assembly if the fan is damaged or loose.
  • Check for bearing noise: Spin the motor by hand. Roughness or grinding indicates worn bearings; replace the motor assembly.
  • Inspect tachometer wiring: Some Vileda models use a small sensor or extra wires on the motor for speed feedback. Ensure the connector is secure and wires are not damaged.
  • Replace control PCB if needed: If the motor and tach wiring are good but E09 persists, the speed control circuit on the PCB may be defective and the board should be replaced.