AEG
Insufficient Brewing Temperature
Coffee is lukewarm or not hot enough, even on maximum temperature setting.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Scaled boiler/thermoblock, Failing temperature sensor (NTC), Weak heating element, Incorrect temperature setting in menu
How to Fix / Troubleshooting
Safety: Allow the machine to cool and unplug before internal inspection.
- Check settings: Enter the settings menu and ensure coffee temperature is set to the highest level.
- Preheat cups: Use the cup warming plate (if available) or rinse cups with hot water to reduce heat loss.
- Descale: Run a full descaling cycle to remove scale from the boiler, which can reduce heat transfer.
- Test NTC and heater: If still lukewarm, test the boiler NTC and heater resistance against AEG specifications and replace the faulty component.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Thermoblock / Boiler Assembly
Check Price on Amazon
We may earn a commission from links on this page.