E03
AEG
Water Flow / Flowmeter Fault
Machine displays E03 and stops; water does not reach the brew unit or steam circuit.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked flowmeter due to limescale, Defective flowmeter sensor, Airlock in hydraulic circuit, Loose or kinked silicone water hose between tank, pump, and flowmeter
How to Fix / Troubleshooting
Safety: Unplug the machine before removing covers or hoses.
- Check water tank: Ensure the tank is fully seated, filled, and the tank valve (if present) opens properly when inserted.
- Bleed air: Remove and reinsert the tank several times. Run a hot water cycle (if possible) to purge air from the system.
- Descale: If the machine can still run a descaling program, perform a full descaling with an AEG-approved descaler to clear partial blockages.
- Inspect flowmeter: Access the internal hydraulic circuit and locate the plastic flowmeter (usually between tank and pump). Check for kinks in hoses and visible debris in the flowmeter inlet.
- Clean or replace: If the flowmeter wheel is stuck or heavily scaled, replace the flowmeter. Ensure all hose clamps are tight and leak-free when reassembling.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Water Flowmeter Assembly
Check Price on Amazon
We may earn a commission from links on this page.