AEG
Dosing / Ejection Fault
Used coffee grounds container does not fill evenly; some cycles produce no puck.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Grinder under-dosing, Brew unit not ejecting pucks correctly, Coffee sticking in chute, Faulty brew unit drive timing
How to Fix / Troubleshooting
Safety: Unplug before internal cleaning.
- Clean chute: Access and clean the coffee chute between grinder and brew unit to remove stuck grounds.
- Check grinder dose: Increase coffee strength and verify that the grinder runs for an adequate time each cycle.
- Service brew unit: Clean and lubricate the brew group, ensuring the ejector mechanism moves freely.
- Inspect drive timing: If pucks are not ejected, inspect the brew drive gears and cams for wear or misalignment.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Coffee Chute / Brew Unit Drive