E06
Ariete
Brew Group Motor / Position Sensor Error
E06 appears and the brew group does not move; you may hear a brief click or hum but no full movement.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Brew group jammed by coffee residues, Stripped gears in drive mechanism, Faulty microswitch or Hall sensor for brew group position, Motor failure
How to Fix / Troubleshooting
Safety first: Unplug the coffee maker before touching the brew group or internal mechanisms.
- Remove and clean brew group (if removable): Open the service door, remove the brew group, and rinse it thoroughly under warm water. Use a soft brush to remove compacted coffee grounds. Let it dry and lightly lubricate moving joints with food-grade silicone grease.
- Check for foreign objects: Inspect the brew chamber and drive area for loose coffee pucks, paper, or plastic pieces that could block movement.
- Reinstall correctly: Reinsert the brew group following the arrows or guides until it clicks firmly into place. An incorrectly seated group can trigger E06.
- Reset cycle: Plug the machine back in and power on. Allow it to complete its self-test. Do not interrupt the cycle.
- If E06 remains: The drive motor, gears, or position sensor may be damaged. Internal disassembly is required; contact an Ariete service center.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Brew Group Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements