Ariete Wet Steam / Condensation in Steam Circuit

Steam wand sprays large droplets of water before producing steam, or never produces dry steam.

Advertisements

Possible Causes

Insufficient preheating, Scale in steam thermoblock, Low steam temperature, Blocked steam outlet partially

How to Fix / Troubleshooting

Safety first: Use a cloth to protect your hand when opening the steam valve.

  • Preheat steam: Activate the steam function and wait until the steam-ready indicator is on. Then open the steam valve into an empty jug for 5–10 seconds to purge water.
  • Descale: Run a descaling cycle with emphasis on the steam function to improve steam quality.
  • Clean wand tip: Remove and clean the steam tip to ensure proper steam flow.
  • If steam remains very wet: The steam thermostat or thermoblock may not be reaching proper temperature and should be checked by a technician.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Steam Thermoblock
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements