Black+Decker
Clock Power Retention / Memory Fault
Clock or timer resets to 12:00 or loses time frequently.
Advertisements
Possible Causes
Frequent unplugging or power outages, failing backup capacitor or battery on control board, defective clock circuit on PCB
How to Fix / Troubleshooting
Safety first: Unplug before accessing the control panel.
Usage considerations:
- Keep the coffee maker plugged into a stable outlet; frequent unplugging will reset the clock on most models.
Control board inspection:
- Remove the control panel and inspect the PCB for a backup capacitor or small battery (if present).
- Check for leakage or bulging; replace the board if components are failing.
When to replace:
- If the clock loses time even when continuously powered, replace the main control PCB.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Main Control PCB
Check Price on Amazon
We may earn a commission from links on this page.