HOT
Black+Decker
Brew Lockout Due to High Plate Temperature
Display shows HOT or a hot surface icon and the coffee maker will not start a new brew cycle immediately after finishing one.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Normal safety lockout while warming plate is hot, stuck or misreading temperature sensor on warming plate, control board not resetting temperature status
How to Fix / Troubleshooting
Safety first: The HOT indication is a safety feature. Do not attempt to bypass it by modifying wiring or sensors.
Normal operation:
- Many Black+Decker models prevent immediate re-brewing to avoid overheating. Wait 5–10 minutes for the warming plate to cool slightly, then try again.
If HOT persists abnormally:
- Unplug the unit and allow it to cool completely (30–45 minutes).
- Plug back in and check if HOT still appears before any brewing. If so, the temperature sensor may be stuck or faulty.
- Access the base and inspect the NTC sensor on the warming plate for secure mounting and good contact.
- Test the sensor resistance at room temperature; compare to expected values from service documentation if available.
When to replace:
- If the sensor reads out of range or is physically damaged, replace the warming plate temperature sensor.
- If the sensor is good but HOT remains, replace the control PCB which interprets the sensor signal.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Warming Plate Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.