Bodum Hot Plate Element or Keep-Warm Thermostat Failure

Bodum coffee maker’s hot plate does not keep coffee warm; brewing completes but the plate stays cold.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open hot plate heating element, Failed keep-warm thermostat, Broken selector switch for keep-warm, Loose wiring to hot plate

How to Fix / Troubleshooting

Safety first: Unplug and cool the unit before opening the base.

Steps to try:

  • Check keep-warm setting: Some Bodum models have a separate keep-warm switch or timer. Ensure it is enabled and not set to 0 minutes.
  • Test with fresh brew: Start a brew cycle and feel (carefully) if the plate begins to warm within 5–10 minutes after brewing completes.
  • Internal check (advanced): Remove the bottom cover and locate the hot plate element and thermostat. Verify all connectors are firmly attached.
  • Continuity test (advanced): Use a multimeter to test the hot plate element and thermostat for continuity. Replace any open component.

If the hot plate assembly is riveted or not serviceable, replacing the entire base/hot plate assembly may be required.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Hot Plate Heating Element / Keep-Warm Thermostat
Check Price on Amazon