E02
Braun Flow Meter / Water Flow Detection Error

Display shows E02 and the coffee maker stops mid‑brew or will not start brewing.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Clogged inlet filter, Scaled internal water lines, Flow meter obstruction or failure, Weak inlet pump

How to Fix / Troubleshooting

Safety: Unplug the coffee maker and allow it to cool completely before any work.

E02 typically indicates the machine is not sensing proper water flow.

  • Check water tank outlet: Remove the Braun water tank and inspect the outlet valve for coffee grounds or mineral buildup. Rinse thoroughly and press the valve a few times under running water.
  • Descale the machine:
    • Fill the reservoir with a 1:1 mixture of white vinegar and water (or Braun‑approved descaling solution).
    • Run a descaling cycle if your model has one, or start a brew cycle without coffee and stop halfway, letting the solution sit for 20 minutes, then complete the cycle.
    • Run 2–3 full tanks of fresh water afterward to rinse.
  • Clean inlet filter: Some Braun models have a small mesh filter at the reservoir inlet. Remove and rinse it under warm water to clear debris.
  • Reset: After descaling and cleaning, unplug the unit for 5 minutes, then plug back in and test.

If E02 remains, the internal flow meter or pump may be defective and will require professional replacement.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Flow Meter
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements