E09
Braun Pump / Pressure System Error

Display shows E09 and the machine stops shortly after starting a brew; pump noise may be intermittent.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Airlock in pump, Weak or failing pump, Severely scaled pump chamber, Blocked internal check valve

How to Fix / Troubleshooting

Safety: Unplug the coffee maker before moving or tilting it.

E09 indicates the pump cannot build or maintain proper flow.

  • Remove airlock: Fill the reservoir completely with water. Plug in the unit and start a brew cycle. Gently tap the sides of the machine and, if safe, slightly tilt it side to side to help move trapped air through the pump.
  • Descale: Run a full descaling cycle to clear scale from the pump and internal lines, then flush with fresh water.
  • Listen to the pump: If the pump is very loud or only hums without moving water, it may be failing.

Persistent E09 after descaling and bleeding air suggests the pump or internal check valve needs replacement.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Water Pump
Check Price on Amazon