Possible Causes

Thermostat out of calibration, Failing heater element (partial), Faulty temperature sensor, Incorrect voltage supply

How to Fix / Troubleshooting

Safety: Use caution when measuring hot water temperature.

Steps:

  • 1. Allow full warm-up: Ensure the brewer has been on long enough for the tank to reach temperature (15–20 minutes).
  • 2. Measure brew temperature: Use a thermometer at the sprayhead during brew. If significantly below spec, proceed.
  • 3. Verify supply voltage: Confirm the brewer is connected to the correct voltage. Low line voltage can reduce heater output.
  • 4. Test thermostat or sensor: Check the thermostat or thermistor for proper operation and replace if out of spec.
  • 5. Inspect heater: While rare, a partially failing heater can produce reduced output. Replace the heater if resistance is abnormal or if it overheats locally.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Tank Heater Element