Bunn
Low Brew Temperature
Bunn coffee maker brews but the water is only lukewarm.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Thermostat out of calibration, Failing heater element (partial), Faulty temperature sensor, Incorrect voltage supply
How to Fix / Troubleshooting
Safety: Use caution when measuring hot water temperature.
Steps:
- 1. Allow full warm-up: Ensure the brewer has been on long enough for the tank to reach temperature (15–20 minutes).
- 2. Measure brew temperature: Use a thermometer at the sprayhead during brew. If significantly below spec, proceed.
- 3. Verify supply voltage: Confirm the brewer is connected to the correct voltage. Low line voltage can reduce heater output.
- 4. Test thermostat or sensor: Check the thermostat or thermistor for proper operation and replace if out of spec.
- 5. Inspect heater: While rare, a partially failing heater can produce reduced output. Replace the heater if resistance is abnormal or if it overheats locally.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Tank Heater Element
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements