A7
De'Longhi Brew Group Home Position Sensor Fault

Machine shows A7 and does not complete startup

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty or misaligned position sensor, Broken sensor magnet on brew group, Loose sensor wiring, Failed position sensor PCB

How to Fix / Troubleshooting

Safety first: Turn OFF and unplug the machine before removing the brew group.

  • Clean brew group: Remove the infuser and clean it thoroughly, especially around any magnets or metal tabs used for position detection.
  • Clean sensor area: With a flashlight, locate the position sensor area inside the brew group compartment (often near the drive gear). Gently clean away coffee dust with a dry brush or compressed air.
  • Inspect magnets/tabs: Check for missing or broken magnets or plastic tabs on the brew group that align with the sensor. If broken, the brew group may need replacement.
  • Reinstall and test: Reinsert the brew group, ensuring it is fully locked. Power ON and observe whether the machine completes its startup cycle.
  • If A7 persists: The position sensor or control board may be defective. Professional diagnosis and replacement are required.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Brew Group Position Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements