E06
Dualit Keypad / User Interface Communication Error

E06 appears and the machine will not start a brew cycle; buttons may be unresponsive or random.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose ribbon cable between control panel and main PCB, Moisture ingress into control panel, Failed touchpad or button PCB, Faulty main control PCB interface

How to Fix / Troubleshooting

Safety first: Unplug the coffee maker before removing the control panel or top cover.

Step-by-step:

  • Dry the control area: If the error appeared after a spill, leave the machine unplugged for 24 hours in a dry environment to allow moisture to evaporate.
  • Inspect ribbon cable: Remove the top/front panel to access the keypad ribbon cable. Reseat both ends firmly into their connectors.
  • Check for corrosion: Look for green/white corrosion on connectors. Clean gently with isopropyl alcohol and a soft brush.
  • Test buttons: With the machine reassembled, test each button. If some remain unresponsive, the keypad PCB may need replacement.

Note: If reseating cables and drying the panel does not resolve E06, the main PCB or keypad assembly likely requires replacement. This is best handled by a service technician.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Control Panel Keypad PCB
Check Price on Amazon