Dualit Brew Start Inhibit / Safety Interlock

Machine powers on but will not start brewing; brew button lights but nothing happens when pressed.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Portafilter or capsule holder not detected, Brew head microswitch misaligned or faulty, Water tank not seated, Drip tray or used capsule drawer sensor engaged

How to Fix / Troubleshooting

Safety first: Unplug the machine before adjusting any internal switches.

User checks:

  • Check all components are in place: Ensure the portafilter or capsule holder is fully locked in, the water tank is seated, and the drip tray and used capsule drawer are correctly installed.
  • Listen for clicks: When inserting the portafilter or closing the brew head, listen for a distinct click from the microswitch. If absent, the switch may not be actuated.

Advanced checks:

  • Inspect microswitches: Remove the housing around the brew head and drip tray to locate the small microswitches. Check that actuators are not broken and that switches are firmly mounted.
  • Test continuity: Use a multimeter to verify that each switch closes when actuated. Replace any faulty switch.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Brew Head Microswitch
Check Price on Amazon

We may earn a commission from links on this page.