E7
Fellow
Pump Circuit Fault
Display shows “E7” and the brew pump does not run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck or seized pump, Airlock in pump line, Failed pump driver on control PCB
How to Fix / Troubleshooting
Safety first: Unplug the unit.
- Prime the system: Fill the reservoir completely and start a brew cycle. If possible, run a cleaning or hot water cycle to push air out of the lines.
- Listen for pump noise: If you hear humming but no water moves, the pump may be airlocked or blocked. Stop the cycle, wait 1–2 minutes, then retry.
- Descale: Mineral buildup can block the pump. Run a descale cycle following Fellow’s instructions.
- If E7 remains and pump is silent: The pump or its driver circuit is likely failed. Replacement of the pump assembly or control board is required.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Brew Pump Assembly
Check Price on Amazon