E08
Frigidaire Low Voltage / Power Supply Regulation Fault

E08 error appears and the display backlight flickers; the unit may shut off randomly during operation.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failing low-voltage power supply on control board, Loose neutral or line connection, Shorted display backlight circuit, Degraded electrolytic capacitors on PCB

How to Fix / Troubleshooting

Safety: Unplug the coffee maker before opening. Capacitors can hold charge; discharge safely if necessary.

  • 1. Check external power:
    • Test the outlet for proper voltage and ensure no extension cords or power strips are overloaded.
  • 2. Inspect internal connections:
    • Remove the rear or bottom cover to access the main control PCB.
    • Verify that all spade and plug connectors are fully seated and not discolored from heat.
  • 3. Examine the power supply section:
    • On the control board, locate the low-voltage power supply (transformer or switching supply, rectifier, and capacitors).
    • Look for bulging or leaking electrolytic capacitors and burnt resistors.
    • Replace any visibly damaged components or the entire control board if component-level repair is not practical.
  • 4. Check display backlight circuit:
    • If the backlight flickers heavily, inspect the LED driver components and ribbon cable to the display.
    • Reseat the ribbon cable and replace the display module if the backlight is shorting.
  • 5. Reassemble and test:
    • Reinstall covers, plug in, and run a full brew cycle to confirm stable operation and that E08 does not return.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control PCB
Check Price on Amazon

We may earn a commission from links on this page.