E17
Gaggia Rinse Valve / Diverter Valve Error

E17 error and machine cannot perform automatic rinsing

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck 3-way diverter valve, Limescale in rinse valve, Faulty diverter valve coil, Broken valve actuator

How to Fix / Troubleshooting

Safety first: Unplug the machine before accessing internal valves.

Descale and flush:

  • Run a full descaling cycle to dissolve limescale in the diverter valve and rinse circuit.
  • After descaling, run multiple rinse cycles to flush debris.

Valve inspection (advanced):

  • Remove the cover to locate the 3-way diverter valve that directs water between brew, rinse, and waste paths.
  • Check for kinks or blockages in the connected hoses.
  • With the machine powered (exercise extreme caution), listen for the valve clicking when a rinse or brew cycle starts. No click may indicate a failed coil.

If the valve is mechanically stuck or the coil is open, replace the diverter valve assembly. This repair is best performed by a technician due to the complexity of the hydraulic routing.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

3-Way Diverter Valve
Check Price on Amazon

We may earn a commission from links on this page.