Gorenje
Intermittent Power / Thermal or Overcurrent Protection Trip
Machine turns off by itself during brewing or shortly after starting.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Overheating control board, Loose mains connection inside machine, Failing power supply components, Shorting heater or pump drawing excess current
How to Fix / Troubleshooting
Safety first: Unplug the machine and allow it to cool before inspection.
Inspection:
- Check ventilation: Ensure the machine has adequate space around it and vents are not blocked.
- Inspect internal connections: Remove the housing and check all mains connectors for looseness or discoloration. Tighten or replace as needed.
- Look for heat damage: Examine the power supply section of the PCB for darkened areas or bulging capacitors. These indicate overheating and require board repair or replacement.
- Test with no load: Run the machine without brewing (idle) to see if it still shuts off. If it only trips under load, a heater or pump may be drawing too much current and should be tested by a technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Power Supply Module
Check Price on Amazon