Gorenje
Mechanical Imbalance / Damping Failure
Machine vibrates excessively and moves on the countertop during brewing.
Advertisements
Possible Causes
Missing or hardened rubber feet, Pump mounts degraded, Machine placed on uneven or slippery surface, Internal components touching housing
How to Fix / Troubleshooting
Safety first: Unplug before internal inspection.
Stabilization:
- Check feet: Ensure all rubber feet are present and not worn flat. Replace missing feet.
- Surface: Place the machine on a stable, non-slippery surface. Use a rubber mat if necessary.
- Inspect pump mounts: Replace hardened or broken rubber mounts supporting the pump.
- Check clearances: Ensure hoses and cables are not pressed tightly against the housing, which can transmit vibration.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Rubber Feet Set
Check Price on Amazon
We may earn a commission from links on this page.