Gorenje Mechanical Imbalance / Damping Failure

Machine vibrates excessively and moves on the countertop during brewing.

Advertisements

Possible Causes

Missing or hardened rubber feet, Pump mounts degraded, Machine placed on uneven or slippery surface, Internal components touching housing

How to Fix / Troubleshooting

Safety first: Unplug before internal inspection.

Stabilization:

  • Check feet: Ensure all rubber feet are present and not worn flat. Replace missing feet.
  • Surface: Place the machine on a stable, non-slippery surface. Use a rubber mat if necessary.
  • Inspect pump mounts: Replace hardened or broken rubber mounts supporting the pump.
  • Check clearances: Ensure hoses and cables are not pressed tightly against the housing, which can transmit vibration.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Rubber Feet Set
Check Price on Amazon