Grundig Insufficient Brew Temperature

Coffee is not hot enough even when the temperature setting is at maximum.

Advertisements

Possible Causes

Scaled thermoblock, Faulty temperature sensor reading low, Incorrect temperature setting, Preheating not completed

How to Fix / Troubleshooting

Safety first: Beware of hot surfaces and steam when testing temperature.

  • Check settings: Enter the menu and confirm the coffee temperature is set to the highest level.
  • Allow full preheat: Wait until the machine indicates it is ready before starting a brew.
  • Preheat cup: Rinse the cup with hot water from the machine to reduce heat loss.
  • Descale: Perform a full descaling cycle to restore efficient heating in the thermoblock.
  • Service if unchanged: If coffee remains lukewarm, the NTC sensor or thermoblock may be faulty and require replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Thermoblock / Temperature Sensor
Check Price on Amazon