E10
Kenmore Lid / Brew Basket Safety Switch Fault

E10 error appears and the machine will not start brewing; some models beep and flash the error.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Misaligned brew basket, Faulty lid-closed microswitch, Broken actuator tab on lid, Loose switch wiring

How to Fix / Troubleshooting

Safety first: Unplug the coffee maker before inspecting internal switches.

  • Check lid closure: Open and firmly close the top lid. Ensure it latches fully. Remove and reseat the brew basket and filter holder.
  • Inspect for broken plastic tabs: Look for small plastic actuators on the lid or basket that press a hidden switch. If broken, the switch will not engage and the unit will show an error.
  • Clean the area: Coffee grounds can prevent proper closure. Clean around the lid hinge and basket area.
  • Test microswitch (advanced): Remove the top cover to locate the lid or basket microswitch. Press it manually and listen for a click. Test continuity with a multimeter. Replace the switch if it does not operate correctly.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Lid / Brew Basket Microswitch
Check Price on Amazon

We may earn a commission from links on this page.