BREWING
Keurig
Brew Cycle Flow Interruption
Display stuck on “BREWING” but no water comes out; pump may run briefly then stop.
Advertisements
Possible Causes
Clogged exit needle, Blocked K-Cup holder, Severe scale in internal lines, Failing pump under load
How to Fix / Troubleshooting
Safety first: Unplug the brewer and allow it to cool before cleaning needles.
- Clean exit and entrance needles: Remove the K-Cup holder. Use a straightened paper clip to gently clear the holes in the top and bottom needles. Rinse the holder under warm water.
- Run water-only cycles: With no K-Cup inserted, run several brew cycles to flush debris.
- Descale: If flow is still poor, perform a full descale with solution to clear internal mineral blockages.
- Listen to pump: If the pump hums but no water moves even after cleaning and descaling, the pump may be failing and require replacement.
- Do not force objects deep into needles: This can damage seals and internal tubing.