Keurig
Brew Head Seal Failure
Water leaks from around the top of the K-Cup holder during brewing.
Advertisements
Possible Causes
Worn or torn upper gasket, Misaligned K-Cup holder, Excessive pressure from clog, Debris on sealing surfaces
How to Fix / Troubleshooting
Safety first: Allow the brewer to cool before touching the brew head.
- Clean sealing surfaces: Wipe the underside of the lid and the rim of the K-Cup holder with a damp cloth to remove coffee residue.
- Inspect upper gasket: Look for cracks, flattening, or tears in the rubber seal around the upper needle. Replace if damaged.
- Clean needles: Clear any clogs that could cause overpressure.
- Ensure proper pod seating: Insert the K-Cup fully and close the lid firmly until it latches.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Brew Head Gasket
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements