E03
L’OR No Water Flow / Pump Prime Failure

E03 appears and no water comes out of the spout, pump noise may be loud or intermittent.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Empty water tank, Airlock in pump, Blocked inlet filter in water tank, Defective ULKA pump

How to Fix / Troubleshooting

Safety: Disconnect power before handling the machine.

  • Check water tank: Ensure the L’OR water tank is filled above the minimum mark and properly seated.
  • Prime the pump: With the tank full, plug in the machine, power it on, and run 3–4 rinse cycles without a capsule. If the pump is noisy but no water flows, stop and refill the tank, then try again.
  • Clean tank filter: Remove the tank and inspect the outlet filter or valve at the bottom. Rinse under warm water and remove any debris.
  • Descale: If some water flows but E03 appears, run a full descaling cycle to clear internal scale from the pump and heater.
  • If still no flow: The vibration pump may be seized or electrically open. Replacement of the pump and possibly the pump check valve is required by a qualified technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Vibration Pump (ULKA type)
Check Price on Amazon