L’OR
Restricted Flow / Partial Blockage
Very little coffee comes out, or brewing stops early with a small amount in the cup.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Clogged piercing needles, Heavy limescale in hydraulic circuit, Blocked flow restrictor, Partially blocked coffee spout
How to Fix / Troubleshooting
Safety: Unplug and let the machine cool.
- Clean needles: Open the capsule lever and gently clean the piercing needles with a soft brush. Do not insert metal pins that could damage them.
- Descale: Run a full descaling cycle using L’OR‑approved descaler.
- Clean spout: Remove and rinse the coffee outlet thoroughly.
- Test without capsule: Run a rinse cycle. If flow is still weak, internal components like the flow restrictor or thermoblock may be blocked and require professional cleaning or replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Thermoblock Heater Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements