ALARM 8
La Marzocco Low Line Pressure / Inlet Flow Fault

Machine displays ALARM 8; low water pressure or flow is detected, shots are weak or do not start properly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Insufficient mains water pressure, clogged inlet water filter, blocked or stuck inlet solenoid valve, partially closed shutoff valve

How to Fix / Troubleshooting

Safety first: Turn OFF and unplug the machine before disconnecting any water lines. Have towels ready for spills.

Steps to resolve ALARM 8:

  • Verify mains pressure: Ensure the building water supply is on and that pressure meets La Marzocco specifications (typically 2–6 bar). If pressure is low, consult a plumber.
  • Check shutoff valves: Confirm that any under-counter or inline shutoff valves feeding the machine are fully open.
  • Inspect and replace inlet filter: Locate the inline water filter or softener cartridge feeding the machine. If it is old or heavily restricted, replace it. Some installations also have a mesh strainer at the machine inlet; remove and clean it.
  • Check inlet solenoid valve: Access the machine’s inlet solenoid. With power applied (for qualified users), start a fill or brew cycle and listen for a click. If the coil energizes but no water flows, the valve may be blocked with debris.
  • Clean or replace solenoid: Isolate water, depressurize, then remove the solenoid valve. Clean the internal screen and orifice. If the coil is burned or the valve body is damaged, replace with a La Marzocco-approved inlet solenoid.
  • Re-test: Restore water and power, then test flow. If ALARM 8 persists despite good pressure and a clean inlet path, contact a technician to check the flow sensor or control board.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Inlet Solenoid Valve
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements