Boiler Overpressure / Safety Valve Venting
Water or steam escapes from the safety valve on top of the boiler.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed pressurestat or pressure sensor allowing overpressure, scaled or sticking safety valve, incorrect pressure setting, blocked steam outlet causing pressure buildup
How to Fix / Troubleshooting
Safety first: If the safety valve is venting, turn OFF and unplug the machine immediately. Keep clear of escaping steam and hot water.
Steps:
- Allow to cool: Wait until the boiler has cooled and pressure has dropped to zero.
- Inspect pressure control: Check the pressurestat or electronic pressure sensor for proper operation. Replace if it allows pressure above the rated safety valve setting.
- Check safety valve: If the valve continues to leak at normal pressure, it may be fouled with scale. Replace the safety valve; do not attempt to repair or adjust it.
- Verify pressure setting: After replacing components, confirm that boiler pressure stays within La Marzocco’s specified range.