E01
Lavazza
NTC Sensor Short Circuit
Machine shows E01 and does not start; may occur immediately after power-on.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Shorted brew temperature sensor, Damaged sensor wiring harness, Moisture on sensor connector, Control board input fault
How to Fix / Troubleshooting
Safety first: Unplug the machine and allow it to cool before accessing internal components.
Step 1 – Dry and reset
- If the machine was recently descaled or exposed to heavy steam, allow it to dry for several hours.
- Unplug for 10 minutes, then retry.
Step 2 – Inspect sensor wiring (advanced)
- Remove the cover and locate the brew thermoblock and its NTC sensor.
- Check the sensor cable for cuts, pinches, or melted insulation.
- Ensure the connector is clean and fully seated on the control board.
Step 3 – Replace sensor (for technicians)
- If the sensor measures near 0 Ω (short) at room temperature, replace it with the correct Lavazza NTC sensor.
- If wiring and sensor are good, the control board may have a defective input circuit.
When to seek service
- E01 usually requires professional diagnosis if basic drying and connector checks do not resolve it.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Brew Temperature Sensor (NTC)
Check Price on Amazon
We may earn a commission from links on this page.