Lelit
Excessive Brew Pressure
Brew pressure too high; gauge spikes above 12 bar and shots are very slow or bitter.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
OPV adjusted too high, Blocked OPV return line to tank, Scale buildup in OPV, Using blind basket or too fine grind during normal shots
How to Fix / Troubleshooting
Safety first: Turn OFF and unplug before internal adjustments.
- Verify technique: Ensure you are not accidentally using a blind basket for normal shots and that your grind is not excessively fine.
- Check OPV return: Confirm that the OPV discharge hose is not kinked or blocked and that water can return to the tank during a blind shot.
- Adjust OPV: Locate the OPV on your Lelit model (often near the pump). Following Lelit’s instructions, turn the adjustment screw slightly to reduce pressure, checking with a blind basket until you reach about 9–10 bar.
- Clean or replace OPV: If adjustment has little effect, remove and descale the OPV. Replace the OPV assembly if the internal spring or seat is damaged.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Overpressure Valve (OPV)
Check Price on Amazon