AL8
Lelit Group Head Temperature Sensor / PID Feedback Fault

Machine displays AL8; group head temperature unstable or not reaching setpoint.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty group head NTC sensor (on Lelit models with group probe), Loose sensor mounting on group, Damaged sensor wiring harness, PID controller / main board failure

How to Fix / Troubleshooting

Safety first: Turn OFF, unplug, and allow the group head to cool before touching any metal parts.

  • Check external factors: Ensure the machine has warmed up for at least 20–30 minutes. AL8 may appear if the group is extremely cold or if the machine is in a very cold environment.
  • Locate group sensor: On models like the Lelit Bianca and some Mara versions, a temperature sensor is mounted on or near the E61 group. Inspect it for loose screws or poor contact with the group metal.
  • Tighten and clean: If the sensor is loose, gently tighten its mounting screw. Clean any coffee oils or residue between the sensor and group to ensure good thermal contact.
  • Inspect wiring: Follow the sensor cable back to the control board. Check for pinched, cut, or burnt wires and reseat the connector.
  • Replace if needed: If the sensor is physically damaged or readings are erratic, replace with a compatible Lelit group head NTC sensor. If a new sensor does not resolve AL8, the PID / main control board may be defective.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Group Head NTC Temperature Sensor
Check Price on Amazon